Ecosoft МО 36 8" RO System without membrane

Ecosoft MO 36 industrial reverse osmosis system is a turnkey solution for industrial water challenges, that includes pilot studies, engineering and manufacturing, commissioning and maintenance.
Ecosoft reverse osmosis systems are used in food and pharmaceutical industry, energy, chemical, semiconductor manufacturing, steam boilers and other industrial applications.

- Energy efficiency with Grundfos pump
- Reliable performance with quality components and engineering
- Individual project evaluation per request
- ISO 9001 certified factory
- CE marked and confirmed to be safe in accordance with EC New Approach Directives
Description ...

65367.00 €
Compare products

Technical Characteristics

Size and weight

MO36
Dimensions, H×W×D: 
2100 × 7000 × 2500
 mm
Filter weight 
1700
 kg

Equipment  
  • Grundfos® CR 45-4-2 high-pressure pump — 1 pc
  • 8040-6 membrane vessels — 6 pcs
  • Stainless steel housing with 7 PP 2,5 × 40″ filter — 2 pcs
  • Motorized feed water in, flush out butterfly valves — 2 pcs
  • Balancing concentrate reject, concentrate recycle valves — 2 pcs
  • Electrical cabinet with Ecosoft controller — 1 set
  • Piping, instrumentation — 1 set
  • Steel frame — 1 set  

Options

  • Filmtec™ XLE-440 / ECO PRO-440 or Ecosoft ELP-8040 membranes
  • Dosing pump for antiscalant or other RO chemicals
  • Permeate inlet for permeate membrane rinse
  • Raw water blending line

Сonnections

  • Influent water — DN100 (flange)
  • Permeate — DN80 (flange)
  • Concentrate — DN100 (flange)
  • CIP inlet — DN80 (flange)
  • CIP return — DN80 (flange)

Technical data

  • Permeate capacity¹ — 36 m³/h
  • Permeate recovery² — 75%
  • Maximum TDS — 3000 mg/L
  • Influent flow demand — 50…60 m³/h (service)
  • Operating pressure — 8…12 bar
  • Maximum pressure — 14 bar
  • Electrical requirements — 380...400 V, 50 Hz (3 ph)
  • Electrical power — 22 kW
  • Prefilter rating — 5 μm
    ¹ depends on feed water TDS, temperature, and permeate recovery
    ² for low scaling/fouling water

Feed water requirements

  • TDS — 3000 mg/L
  • hardness — 150 mg/L CaCO₃
  • iron — 0.1 mg/L
  • manganese — 0.05 mg/L
  • hydrogen sulfide — none
  • silicate — 20 mg/L
  • residual chlorine — 0.1 mg/L
  • SDI — 5
  • chemical oxygen demand - 4 mg/L O₂