All new Waterboss A1000 ( S1000 ) Water softener and iron remover

Compact, versatile, economical and reliable 2 in 1 water filtration system for softening and iron removal. It is intended for removal of iron (in concentration up to 14 mg/l), hardness salts and prefiltration of particles up to 20 microns in diameter.

The unique tank design and the smallest ion exchange resin granules in the fill allow the system to operate quietly, quickly and very economically.
The consumption of salt and water for regeneration is much lower than in classic column-type water softeners.
Description ...

1050.00 € 870.00 €
Compare products
AQUAPHOR
WATER SOFTENER AND IRON REMOVER.
1. Compact frame.
2. Low dispersible sorbent
with high capacity provides productivity and full of iron, manganese and hardness of obliterating.
3. Patented valve with personal development ensures continuous filtering process lifelong.
4. The patented mesh distributor distributes the flow of treated water throughout the sorbent volume.
5. Cover slider for easy access to the salt tank and provides compact filter. 
6. Controller with a large information screen.
7. Bypass valve 
8. Ultra tank 
from durable glass-filled plastic.
  • EFFECTIVE
  • RELIABLE
  • COMPACT
  • PRODUCTIVE
​+ The simultaneous removal of iron, hardness and manganese.
+ Durable stainless steel liner and the drain hose in complect.
+ Reliability and durability of the pressure in the entire range from 1.5 to 7 atm.
+ Counter current regeneration in the clamped layer effectively restores the filter of accumulated dirt.


Model                                                                                                1000
___________________________________________________________________________
Maximal capacity, gram                                                                       2061
___________________________________________________________________________

The maximum concentration of dissolved iron and manganese, mg / l       10
___________________________________________________________________________
The minimum pH                                                                                   6
___________________________________________________________________________

The temperature of the water and the environment, ° C                           4 - 49 
___________________________________________________________________________
The water pressure is high-low bar                                                          7
___________________________________________________________________________
The minimum water flow
on backflushing, l / min                                     7.6
___________________________________________________________________________

Maximum flow to drain during regeneration, l / min                                   9.1
___________________________________________________________________________
Nominal / maximum flow rate, l / min                                                   28 / 42
___________________________________________________________________________
The pressure loss at a flow 6 gpm (22.7 l/min) bar.                                    1     
___________________________________________________________________________
Capacity in regime HE, kg of salt / gram of hardness                            1.1 / 680       
___________________________________________________________________________
Saver of salt HE, min/l                                                                          24/67
___________________________________________________________________________
Capacity mode HC, kg of salt / gram of hardness                                 3.8 / 1846
___________________________________________________________________________
High-capacity mode HC, l                                                                      97.3
___________________________________________________________________________
The maximum capacity mode in the AU, kg / gram                              > 6.8 / 2061
___________________________________________________________________________

Maximum capacity mode AU, min / l                                                      50 / 122   
___________________________________________________________________________
Regeneration method                                                                       by water meters 
___________________________________________________________________________
Power options                                                               12 VAC; 50 / 60 Hz; 0.015 kW-hr
___________________________________________________________________________

Connection ports (NTP)                                                                        1” (MNPT)
___________________________________________________________________________

The minimum diameter of the drain line (mm)                                            5/8 (16)         
___________________________________________________________________________
The size of the filter tank (ID x H), inch (cm)                                     10.5 x 26 (26.7 x 66)
__________________________________________________________________________
  
Height, cm                                                                                              79.5
__________________________________________________________________________
       
Base, cm                                                                                           40.4 x 48.5
__________________________________________________________________________

Gross weight (approximately), kg                                                               48
__________________________________________________________________________


Loading type and its amount
Super petite ion exchange resin                                                           1.0 cu. ft. (28 l)    
___________________________________________________________________________