Akvafors SF 1252 Water Softener (softening, iron remover)

Aquafors SF 1252 solves several problems associated with the presence of hardness salts in water.
Water softening systems are based on a filter material - an ion exchange resin that is able to exchange ions with the solution. It traps pollutant ions.
Description ...

621.00 €
Compare products
Equipment characteristics:
  • Effectively softens, reduces iron, manganese and ammonium content in water
  • High quality ingredients
  • The service life of the filter is 5-7 years
  • Intended for summer houses, private houses, commercial establishments, etc
  • Automatic purification and regeneration after water consumption
  • Regeneration with salt tablets (NaCl)
  • A sewer connection is required. Rinsing water can be discharged into the Biological WWTP
  • Easy installation and operation
  • The device does not remove the smell. In addition, B520-12 or AERO equipment must be installed
  • Economical operation
WATER QUALITY PROBLEM
Hardness is a set of natural water properties associated with the concentration of alkaline earth metal salts, most often calcium and magnesium salts, in the water. Although hard water is not harmful to human health, it can pose a serious threat to various appliances, such as washing machines, boilers, dishwashers and pipes, by settling in it as scale. When using such water for laundry, a larger amount of detergent is required. Hardness will reduce the service life of sanitary equipment and increase energy consumption.
THE SOLUTION
The solution for domestic and industrial applications is water softening with  DOWEX HCR S/S  series ion exchange resin filters (reduces scale) regenerated with salt (NaCl). The water softener also efficiently removes iron and manganese.
OPERATION OF FILTERS
In the purification process, a reagent (NaCl, or salt in tablets -  granules ) is used, which is used for the regeneration of the filtering material (resin). The rinse water from this facility can be discharged to biological WWTPs (wastewater treatment plants). The AKVAFORS SF series kit consists of a filter column, a control unit and a salt tank. The filter column is filled with ion exchange resin (cationite), which reduces hardness and filters iron. The control unit performs automatic flushing of the machine. The salt tank is filled with a reagent (NaCl, in salt tablets) for resin regeneration. Depending on the amount of resin and the quality of the water, the machine has a certain amount of water to be cleaned.
FILTER MANAGEMENT
AKVAFORS SF series equipment is equipped with a RUNXIN'' control unit complete with a flow meter, which rinses the filters according to the amount of water consumed. Thanks to the flow meter, flushing will be carried out according to the set amount of water. The flow meter saves rinsing water and salt. The device can be equipped with a bypass line, which allows you to quickly disconnect the device and perform preventive maintenance. In the control unit, all information is saved even if the electricity goes out. The device has many parameters that can be adjusted according to your needs, such as rinsing time, frequency, reagent consumption, etc. It is possible for the device to change the degree of water hardness with a specific control unit housing (additional equipment). The device also performs the function of deironing water, but the iron content must not exceed _____ mg/l.    

 
Technical parameters Unit of measure  SF 1252
Productivity* Qnom м3/st 1.8
Amount of rinsing water LITER  200-250
Minimum intensity of scalorna  м3/st  1.5
Tank size (diameter) inches 12
Tank volume  LITER  85
A lot of filter material. in the tank LITER  58
Overall size of the device:    
Length (L) m 0.99
Height (H)  m 0.30
Height (H)  m 1.48
Water add. In/Out/Can inches 1''
Runxin control unit.    1'' 3/4
Cleaning options    Hardness, iron, manganese, turbidity
Tank material   FRP (Fiberglass)
Filter material   Ion exchange resin DOWEX, quartz sand 1x3 mm, 3x5 mm
Working pressure  bar 2-6
Electrical connection    220W, 50Hz, 1 phase
Electricity consumption  IN  3 In
<span style="color: rgb(67, 69, 75); font-family: Rubik, " source="" sans="" pro",="" helveticaneue-light,="" "helvetica="" neue="" light",="" neue",="" helvetica,="" arial,="" "lucida="" grande",="" sans-serif;="" font-size:="" 16px;="" text-align:="" justify;"=""> 
* Filtration speed 25 BV/h
**Filtration rate 40 BV/h
*** Quantity may double due to changes in incoming water quality
OPERATION OF THE EQUIPMENT                     
Although salt tablets are used for plant regeneration, the water after the filter can be used for drinking and other necessities of human life. The device requires connection to electricity (one outlet), sewage and incoming/outgoing water pipe with a minimum pressure of 2.5 bar. The device can be placed in wet rooms or in underground shafts made of ropes.  
RECOMMENDATIONS:
  • Before choosing a device, it is recommended to carry out water testing to determine the chemical composition of the water
  • It is preferable to install a mechanical cleaning filter before the device to ensure a longer service life of the device
AKVAFORS additional equipment options:
  • Condensate insulation for the tank
  • By-pass – you don't have to make your own bypass from three ball valves. For more convenient assembly
Width cm
Height cm
Length cm
Svar kg
33.00
150.00
65.00
90.00