Aeration equipment 2160 CLACK WS1.5 with oil-free compressor and pulse counter
6372.00 €
Compare products
WATER QUALITY PROBLEM
Iron and manganese often causes the main problem of the waterworks. When water gets in contacts with air, it changes the colour, turbidity increases and sediments appears. Water has a metallic taste. Water pipes are clogged and sanitation at the consumer becomes dirty. Suggested concentration of iron should be 0.2 mg/l and manganese 0.05mg/l.
SOLUTION
Aqaphor Aerācija series filters are designed to purify water from turbidity, colorfulness, iron, manganese and odor for private houses. Mainly it is used for groundwater purification.
OPERATING PRINCIPLE
When water is aerated, iron, manganese and mechanical impurities form sediment, which can be filtered. Suspended solids are filtered through filtering material, which has been poured in to filter. Filters depending on pollution levels and water consumption have to be rinsed regularly. Filters after rinsing are regenerated and can purify water. Equipment consists from reactor, filter and compressor.
FILTER MATERIAL
For water purification filtering material Birm and quartz sand with different grain size (0.4-0.8 mm, 0.7-1.25 mm, 1-3 mm, 3-5 mm) is being used.
AIR SUPPLY
For water aeration it is necessary to install air compressor. Air is injected in the water before it enters reactor.
PRECONDITIONS
The equipment need sewer and electricity 220V connection, input water pressure with a minimum pressure of 2.5 bar, the room temperature above 0° C, the water temperature to 25° C as well as correct system connection.
Additional equipment options:
Iron and manganese often causes the main problem of the waterworks. When water gets in contacts with air, it changes the colour, turbidity increases and sediments appears. Water has a metallic taste. Water pipes are clogged and sanitation at the consumer becomes dirty. Suggested concentration of iron should be 0.2 mg/l and manganese 0.05mg/l.
SOLUTION
Aqaphor Aerācija series filters are designed to purify water from turbidity, colorfulness, iron, manganese and odor for private houses. Mainly it is used for groundwater purification.
OPERATING PRINCIPLE
When water is aerated, iron, manganese and mechanical impurities form sediment, which can be filtered. Suspended solids are filtered through filtering material, which has been poured in to filter. Filters depending on pollution levels and water consumption have to be rinsed regularly. Filters after rinsing are regenerated and can purify water. Equipment consists from reactor, filter and compressor.
PRESSURE TANK
Pressure filter tanks are made from fiberglass with inner PE coating that can hold pressure up to PN10.FILTER MATERIAL
For water purification filtering material Birm and quartz sand with different grain size (0.4-0.8 mm, 0.7-1.25 mm, 1-3 mm, 3-5 mm) is being used.
CONTROL UNIT
The filter is equipped with an automatic Clack control which performs filtering and rinsing sequences automatically. Usually rinsing is performed at 2:00 at night.AIR SUPPLY
For water aeration it is necessary to install air compressor. Air is injected in the water before it enters reactor.
PRECONDITIONS
The equipment need sewer and electricity 220V connection, input water pressure with a minimum pressure of 2.5 bar, the room temperature above 0° C, the water temperature to 25° C as well as correct system connection.
SYSTEM MAINTENANCE
Filters will provide with good quality water if operating personnel will ensure proper air supply, and unnecessary air removal and regular rinsing processes. Water purification system does not require specific chemical admixtures that have to be refilled. Additional equipment options:
- Condensate isolation for tank;
- By-pass valve – For easier assembly.
Technical parameters of equipment
Parameters |
Unit |
Аeration 2160 |
Flow rate Qnom |
m3/h |
2.6 |
The amount of water for regeneration |
m3 |
0.35 |
Minimum flow rate for rinsing |
m3/h |
5.3 |
Tank size (diameter) |
inches |
21 |
m |
0.53 |
|
Tank volume |
liters |
316 |
The amount of filtering material |
liters |
211 |
Length |
m |
1.89 |
Width |
m |
0.53 |
Height |
m |
2.00 |
Connection. in /ext/kan. |
inches |
1 ½” |
Управляющий блок Clack |
|
|
Filtration |
|
Iron, manganese, turbidity, odor, colorfulness |
Tank material |
|
FRP (fiberglass) |
Filtering material |
|
Birm, silica sand 0.4x0.8 mm, 0.7x1.25 mm, 1x3 mm, 3x5 mm |
Operating pressure |
bar |
2-6 |
Electric Connection |
|
220V, 50Hz, 1 фаза |
Electricity consumption |
W |
3 W |